Inverter Ceiling Cassette
The SLZ & PLA Series ceiling cassette inverter-type heat pumps, combine powerful cooling and heating in an elegant cassette design that recesses into the ceiling.
The Perfect Size: Attractive and inconspicuous. Choice of Infra Red or Wired.
The SLZ-KA Series is perfect for both residential and small business applications as it offers Inverter Technology and quiet operation. The compact size of this range is ideal for installation in offices with ceiling tiles, while the lightweight design helps to make installation easier and more convenient.
| SLZ-KA25VA |
|
Compact Cassette indoor unit - DC inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 2.5/3.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA25VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.
|
![]() |
| SLZ-KA25VAL |
Compact Cassette indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 2.5/3.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA25VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.
|
![]() |
|
| SLZ-KA35VA |
Compact Cassette indoor unit - DC inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 3.5/4.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA35VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.
|
![]() |
|
| SLZ-KA35VAL |
Compact Cassette indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 3.5/4.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA35VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.
|
![]() |
|
| SLZ-KA50VA |
Compact Cassette indoor unit - DC inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 4.6/5.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.
|
![]() |
|
| SLZ-KA50VAL | Compact Cassette indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 4.6/5.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System. | ![]() |
| SUZ-KA25VA |
|
Outdoor unit for MFZ-KA25VA, SLZ-KA25VA(L). (WxDxH, mm): 800 x 285 x 550. Weight: 33kg.
|
![]() |
| SUZ-KA35VA | Outdoor unit for MFZ-KA35VA, SLZ-KA35VA(L), SEZ-KA35VA (WxDxH, mm): 800 x 285 x 550. Weight: 37kg. | ![]() |
|
| SUZ-KA50VA-1TH-A | Outdoor unit for MFZ-KA50VA, SLZ-KA50VA(L), SEZ-KA50VA, PCA-RP50GA (WxDxH, mm): 840 x 330 x 850. Weight: 53kg. |
![]() |
The new energy saving "360º i-See Temperature Sensor". Which automatically searches out temperature disparities over a wide area. Thanks to this advanced sensing technology, all areas of the room are kept at an optimal temperature.
The automatic elevating panel. With 8 levels of elevation up to 4 meters of travel for easier filter cleaning and other maintenance.
| PLA-RP60BA |
|
Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 5.7/6.9kW. (WxDxH, mm): 840 x 840 x 258 (Panel: 950 x 950 x 35). Weight: 23kg + (Panel: 6kg). Liquid / Gas Pipe (OD, mm): 6.35 / 15.88. Requires a SUZ-KA60VA outdoor unit or can be used in a customisable MXZ-4A71, 4A80, 5A100, 8A140VA or PUHZ Multi-Split System.
|
![]() |
| PLA-RP71BA |
Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 840 x 840 x 258 (Panel: 950 x 950 x 35). Weight: 23kg + (Panel: 6kg). Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP71VHA outdoor unit or can be used in a customisable MXZ-4A80, 5A100, 8A140VA or PUHZ Multi-Split System.
|
![]() |
|
| PLA‑RP100BA |
Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 10.0/11.2kW. (WxDxH, mm): 840 x 840 x 298 (Panel: 950 x 950 x 35). Weight: 30kg + (Panel: 5kg). Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP100VHA deluxe, PUHZ-BP100VHA standard outdoor unit or can be used in a customisable PUHZ Multi-Split System.
|
![]() |
|
| PLA-RP125BA |
Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 12.5/14.0kW. (WxDxH, mm): 840 x 840 x 298 (Panel: 950 x 950 x 35). Weight: 32kg + (Panel: 5kg). Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP125VHA deluxe, PUHZ-BP125VHA standard outdoor unit or can be used in a customisable PUHZ Multi-Split System.
|
![]() |
|
| PLA-RP140BA |
Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 14.0/16.0kW. (WxDxH, mm): 840 x 840 x 298 (Panel: 950 x 950 x 35). Weight: 32kg + (Panel: 5kg). Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP140VHA deluxe, PUHZ-BP140VHA standard outdoor unit.
|
![]() |
|
| PAC-SA1ME-E |
360º i-See Sensor Module. This 360º i-See Sensor is added as an option to the PLA-RP BA Series Grille. The sensor measures the floor temperature to ensure the correct comfort level is set in the room. For PLA-RP~BA Series Ceiling Cassette indoor units.
|
![]() |
|
| PLP-6BAJ |
Elevating Panel. For easy filter cleaning with the new safety standards for maintenance above 3 meters this feature enables filter cleaning by a simple press of a button on a infra red remote. For PLA-RP~BA Series Ceiling Cassette indoor units. |
![]() |
| SUZ-KA60VA-1TH-A |
|
Outdoor unit for SEZ-KA60VA, PLA-RP60AA, PCA-RP60GA (WxDxH, mm): 840 x 330 x 850. Weight: 53kg.
|
![]() |
| PUHZ-RP71VHA |
Outdoor unit for PKA-RP71FAL, PLA-RP71AA/BA, PCA-RP71GA or PEA-RP71EA. (WxDxH, mm): 950 x 330(+30) x 943.
|
![]() |
|
| PUHZ-RP100VHA2 |
Deluxe outdoor unit for PKA-RP100FAL, PLA-RP100AA/BA, PCA-RP100GA or PEA-RP100EA and also for use as a Medium Multi-Split system. (WxDxH, mm): 950 x 330(+30) x 1350. Cooling/Heating capacity: 10.0/11.2kW. Weight: 121kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. When being used as a Twin (2x 5.0kW) Multi-Split system a Twin (MSDD-50WR-E) Distribution Pipe Kit is needed.
|
![]() |
|
| PUHZ-RP125VHA2 |
Deluxe outdoor unit for PLA-RP125AA/BA, PCA-RP125GA/HA or PEA-RP125EA and also for use as a Medium Multi-Split system. (WxDxH, mm): 950 x 330(+30) x 1350. Cooling/Heating capacity: 12.5/14.0kW. Weight: 116kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. When being used as a Twin (2x 6.0kW) Multi-Split system a Twin (MSDD-50WR-E) Distribution Pipe Kit is needed.
|
![]() |
|
| PUHZ-RP140VHA2 |
Deluxe outdoor unit for PLA-RP140AA/BA, PCA-RP140GA or PEA-RP140EA and also for use as a Medium Multi-Split system. (WxDxH, mm): 950 x 330(+30) x 1350. Cooling/Heating capacity: 14.0/16.0kW. Weight: 116kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. When being used as a Twin (2x 7.1kW) or Triple (3x 5.0kW) Multi-Split system either a Twin (MSDD-50WR-E) or Triple (MSDT-111R-E) Distribution Pipe Kit is needed. |
![]() |
Our new standard inverter outdoor units feature energy saving, compact design, light weight, and basic performances as well.
| PUHZ-BP100VHA |
|
Standard outdoor unit for PKA-RP100FAL, PLA-RP100AA/BA, PCA-RP100GA or PEA-RP100EA. (WxDxH, mm): 950 x 330(+30) x 943. Weight: 66kg.
|
![]() |
| PUHZ-BP125VHA |
Standard outdoor unit for PCA-RP125GA/HA, PLA-RP125AA/BA or PEA-RP125EA. (WxDxH, mm): 950 x 330(+30) x 943. Weight: 80kg.
|
![]() |
|
| PUHZ-BP140VHA |
Standard outdoor unit for PLA-RP140AA/BA, PCA-RP140GA or PEA-RP140EA. (WxDxH, mm): 950 x 330(+30) x 943. Weight: 84kg.
|
![]() |